Determination of resorcinol on glassy carbon electrode modified by carbon nanotube and its application in wastewater analysis Liang Shuxuan 1 , Yuan Chenguang1, Zhang Huankun2, Yang Liu1,Sun Hanwen 1(1College of Chemistry and Environmental Science, Hebei University, Baoding 071002; 2 Environmental Science Academe of Heibei, Shijiazhuang, China) Abstract Adsorptive
stripping method for the determination of resorcinol on multi-walled carbon nanotube
modified glassy carbon electrode (MWNT-GCE) was developed. Cyclic voltammetry was used in
the study of the electrochemical behavior of resorcinol on MWNT-GCE. The sharp peak of
resorcinol appeared at 0.6 V (vs. Ag/AgCl) with the differential pulse voltammetry (DPV).
The experimental parameters were optimized. Anodic peak currents were linear over the
resorcinol concentrations in the range of 5.5กม10-5-3.3กม10-3 g L-1
with a detection limit of 1.1กม10-5 g L-1 and relative standard
deviations of 3.30-6.94% for 7 determinations. The interference of organic and inorganic
species on the voltammetric response was also tested. The proposed method was applied to
the determination of resorcinol in tap water and simulative wastewater samples with an
average recovery of 95.2-104.8%. 1. INTRODUCTION
The chemical modification of electrode (CME) is a field of growing interest in analytical chemistry. The modification of the electrode surface could promote reactivity and selectivity to the base sensor, leading to the development of electrodes for some specific applications[11,12]. It has been demonstrated that CME possesses distinct advantages over conventional electrode in many application areas including electrocatalysis and electrochemical sensors. One of the most important properties of the CME, which has been the subject of considerable study, is their ability to catalyze the oxidation or reduction of some compounds[13,14]. Carbon nanotube is of fullerene-related structures that consist of graphite cylinder closed at either end with cap containing pentagonal ring. It is promising as immobilization substance because of its significant mechanical strength, high surface area, excellent electrical conductivity and good chemical stability. The main advantages of a nanoparticle-modified electrode compared to a macroelectrode are high effective surface area, mass transport, catalysis and control over local microenvironment[15]. In essence the small dimension of nanoparticle brings about convergent rather than linear diffusion, resulting in a higher rate of mass transport to the electrode surface. However, this can modify the appearance of the voltammetric signal due to the increased mass transport overpotential. In view of the excellent properties of carbon nanotube, it has been used to modify different electrodes for determination of chemical and biological species[16]. Not many electrochemical studies of resorcinol have been reported. Nasr et al.[17] and Robson T. S. Oliveira et al.[18] reported the electrochemical oxidation of resorcinol on boron-doped diamond anodes. Cyclic voltammetric study showed that the current density of resorcinol was smaller and no reverse peak was observed. Wang group[19] reported the method of simultaneous determination of hydroquinone, resorcinol, and catechol by voltammetry with single-walled carbon nanotube (SWNT) modified glassy carbon electrode. The detection limit of resorcinol was 3.3กม10-5 g L-1. Each of these studies has reported the electrochemical behavior or the determination of dihydroxybenzene isomers, but so far there is no report on the analysis of resorcinol by voltammetry with multi-walled carbon nanotube (MWNT) modified glassy carbon electrode. This work investigated a new method for the determination of resorcinol by differential pulse voltammetry (DPV) using a glassy carbon electrode modified by multi-walled carbon nanotube, which promoted better electron transfer between the electrode surface and electroactive species in solution. The modified electrode exhibited a remarkable accumulation effect for resorcinol and high sensitivity. The proposed method also displayed good resistance to the interference from some organic and inorganic compounds. 2. EXPERIMENTAL The GCE was previously polished with a piece of SiC sandpaper, then thoroughly washed with doubly distilled water and anhydrous ethanol in the ultrasonic cleaner for 5 min, respectively, and dried in air. MWNT films were prepared by casting 50 mL aqueous dispersion of 1.0 g L-1 MWNT onto GCE, then dried under an infrared light. The modified electrode was activated by immersing in 0.2 mol L-1 NaOH and then cleaned electrochemically by cycling potential scans for five cycles between -1.5 to 1.5 V at a scan rate of 200 mV s-1 and accumulation potential of -1.5 V. 2.4. Analytical procedures 5 mL buffer solution (pH=7.0) was transferred into a dry sample cell and resorcinol standard stock solution was added with definite volume by a micropipette. The above solution was diluted to 10 mL with buffer solution and deoxidized by bubbling with extra pure nitrogen for about 15 min before electrochemical measurements. After a 15 s rest, the DPV method was applied from 0 V to 1.3 V to the modified GCE (versus Ag/AgCl reference electrode). The pulse amplitude, pulse width, accumulation time, accumulation potential was 50 mV, 50 ms, 60 s, -0.4 V respectively. The measured data were recorded by a workstation with 10 mV intervals. Cyclic voltammetry (CV) method was applied for acquiring qualitative information about electrochemical reactions, the cyclic voltammograms were recorded by applying a scan over the potential range from 0 V to 1.3 V to the GCE (versus Ag/AgCl reference electrode). The accumulation time, accumulation potential, and scan rate were 60 s, -0.4 V, and 200 mV s-1, respectively. Data acquisition and treatment were performed with a workstation. 3. RESULT AND DISCUSSION The cyclic voltammograms of this system are shown in Fig. 1. Anodic peak increased obviously after addition of resorcinol and this result suggested that anodic peak of resorcinol was produced on GCE. The anodic peak potential was at 0.6 V on the GCE in pH=7.0 buffer solution. Only one anodic peak was observed and this result confirmed the irreversibility of the electrochemical reaction under investigated conditions. ![]() Fig. 1 Cyclic voltammograms of resorcinol in pH=7.0 buffer solution. a-blank solution, b-5.5กม10-3 g L-1 resorcinol. The accumulation time, accumulation potential, and scan rate were 60 s, -0.4 V, and 200 mV s-1, respectively. 3.2. Influence of modified electrode 3.3. The choice of buffer solution and pH 3.4. Influence of accumulation time and
potential 3.5. Reproducibility 3.6. Linear range and detection limit 3.7. Interferences The interferences from some metal ions, anions and other organic compounds were examined with 5.5กม10-3 g L-1 resorcinol. Measurements of the peak current for each solution were repeated three times and the average current values were obtained. If the presence of a compound altered the average current of resorcinol less than กภ5%, then the compound was considered that did not cause interference. The results showed that 100 folds of Mg2+, Ca2+, K+, Na+, Mn2+, Cd2+, Cu2+, Br-, NO3-, SO42-, CO32-, PO43-, and 100 folds of phenol, methanol and ethanol had no obvious influence on the determination of resorcinol. However, 2 folds excess of ascorbic acid, o-nitrophenol and catechol caused the peak depression about 10%. 3.8. Practical analysis of samples This method was applied to the determination of resorcinol in samples of simulative wastewater and tap water respectively. The simulative wastewater sample was constructed by adding resorcinol and co-existing components in tap water, which contained 5.0กม10-4 g L-1 phenol, 5.0กม10-4 g L-1 ethanol, 1.0กม10-4 mol L-1 NaCl, 1.0กม10-4 mol L-1 Na2SO4 and different amount of resorcinol. The concentration of resorcinol was determined by the standard addition method. The determination of simulative wastewater and tap water was carried respectively by CE method also to validate the proposed method. Results were listed in Table 1. The recoveries and CE method suggested that the proposed method was effective for the determination of resorcinol. Table 1 Determination and results recovery of samples
4. CONCLUSIONS REFERENCES [9] Metzger J, Reiss M, Hartmeier W. Biosens. Bioelectron., 1998, 13 (10): 1077-1082. [10] Kudryasheva N, Kratasyuk V, Esimbekova E, et al. Field. Anal. Chem. Technol., 1998, 2 (5): 277-280. [11] Davis J J, Coles R J, Hill H A O. J. Electroanal. Chem., 1997, 440: 279-282. [12] Katz E, Willner I, Wang J. Electroanal., 2004, 16: 19-44. [13] Britto P J, Santhanam K S V, Ajayan P M. Bioelectrochem. Bioenerg., 1996, 41: 121-125. [14] Ozkan S A, Ozkan Y, Senturk Z. J. Pharm. Biomed. Anal, 1998, 17: 299-305. [15] Davis J J, Green M L H, Hill H A O, et al. Inorg. Chim. Acta, 1998, 272: 261-266. [16] Luo H X, Shi Z J, Li N Q, et al. Anal. Chem., 2001, 73: 915-920. [17] Nasr B, Abdellatif G, Canizares P, et al. Environ. Sci. Technol., 2005, 39: 7234-7239. [18] Oliveira R T S, Salazar-Banda G R, Santos M C, et al. Chemosphere, 2007, 66: 2152-2158. [19] Wang Z H, Li S J, Lv Q Z. Sensors and Actuators B, 2007, 127: 420-425. กก | |||||||||||||||||||||||||||||||||||||||